During the inspection of the electrical service entrance and panel box items inspected are:
-Observe service entrance cables for integrity of insulation, drip loop, separation of conductors at weatherheads and the proper clearance of overhanging power lines. -Inspect that the drop, weatherhead and mast are securely fastened. -Inspect for the presence of a grounding electrode conductor in the service where visible, secure connection to the grounding electrode or grounding system. -Inspect all accessible main and subpanels to ensure thay are secured to the structure, appropriate for their location, weather-tight if exposed to the weather. -Inspect that inside cover (dead front) is secured properly and panel knock outs are filled in with the appropriate plugs. -Insure that all breakers are identified on the dead front panel. -Inspect the condition of the wiring in the panels, determine its type (copper or aluminumum). -Note the presence or absence of appropriate connections, such as copper/aluminum approved devices, pig-tailed connections or crimp connections. -Inspect and ensure the presence of main disconnects. -Report the usage of recalled Stablock breakers. -Report rust or other deterioration of the exterior electrical service panel. |